Disclaimer: Please note that images or illustrations may differ from the actual products due to presentation reasons and are therefore non-binding. Technical changes and errors are excepted. For the most accurate information, contact our customer service team.
Leister VACUUM BOX Weld Seam Leak Testing Device

In Stock
Transparent impact-resistant plastic, a durable long-life seal, clearly arranged high-quality fittings, and ergonomic handle design make the VACUUM BOX a robust, practical field instrument for the repetitive positioning, vacuum application, and manometer reading sequence that systematic weld seam leak testing on civil project sites requires across hundreds or thousands of test positions per installation.
- Large-format rectangular vacuum tester with 810 x 310 mm test area for efficient seam coverage
- Maximum vacuum of 0.5 bar with manometer scaled in bar and inHg
- Transparent impact-resistant plastic for direct visual observation during testing
- Durable perimeter seal for consistent vacuum integrity across repeated site use
- Thumb-pressure vent for easy single-operator positioning and repositioning
- Ergonomic handle and clearly arranged high-quality fittings for site usability
- Designed for use with the Leister VACUUM PUMP for vacuum generation
- Manufactured in Switzerland

Like this product?
Speak to an Expert!
08:00 AM - 08:00 PM
Leister VACUUM BOX - Large-Format Rectangular Vacuum Testing Device for Geomembrane Weld Seam Leak Detection
The Leister VACUUM BOX is a rectangular non-destructive weld seam leak testing device with an 810 x 310 mm test area applying up to 0.5 bar of vacuum to geomembrane overlap weld seams – manufactured from transparent, impact-resistant plastic with a durable perimeter seal, ergonomic handle, high-quality fittings, thumb-pressure vent, and bar and inHg manometer – designed for leak detection in geomembrane plastic welding seams on landfill containment liner systems and civil GEO applications, used with the Leister VACUUM PUMP for vacuum generation.
Large-Format Non-Destructive Vacuum Testing for Geomembrane Weld Seam Quality Assurance
Systematic vacuum testing of geomembrane weld seams on large civil liner installations – landfill containment cells, reservoir liners, canal waterproofing systems, and environmental barrier structures – requires a vacuum testing instrument that balances testing sensitivity with inspection programme efficiency. The fundamental tension in geomembrane vacuum testing is between test area per position and the thoroughness of seam coverage: a smaller testing instrument provides easier handling but requires more individual test positions – and therefore more total inspection time – to cover the same total seam length. A larger instrument covers more seam per position, accelerating coverage of long straight seam runs, but must remain manageable enough for single-operator field use across the terrain conditions of active civil project sites.
The VACUUM BOX is positioned as the large-format vacuum testing instrument in the Leister GEO quality assurance range – a rectangular device whose 810 x 310 mm test area covers substantially more seam length per position than the square 320 x 320 mm VACUUM BELL. This dimensional advantage is directly significant on large geomembrane installations where the total number of test positions required to cover the full seam network is a practical constraint on the pace and completeness of the quality inspection programme. Used alongside the VACUUM BELL for corner and detail sections, the VACUUM BOX enables an efficient two-instrument vacuum testing programme that covers long field seam runs with the larger instrument and addresses corners and confined geometry with the smaller one – completing comprehensive weld seam quality verification within the inspection windows that civil installation programmes across Oman and the GCC allow.
VACUUM BOX Testing Capabilities and Field Quality Assurance Features
- 810 x 310 mm Test Area for Efficient Large-Seam Coverage: The rectangular 810 x 310 mm test footprint covers approximately seven times the test area of a typical round vacuum bell per position – enabling quality control personnel to progress more rapidly through the test position sequence on long straight geomembrane seam runs, reducing the total inspection time required for complete seam network vacuum testing on large-area liner installations without reducing the vacuum sensitivity applied to each test section.
- 0.5 Bar Maximum Vacuum for Reliable Leak Detection: The VACUUM BOX applies up to 0.5 bar of vacuum across the enclosed seam section – creating a differential pressure sufficient to open and reveal fine fusion voids, incomplete overlap bond zones, and fine leak paths that represent genuine weld quality defects in geomembrane overlap seams, while the transparent plastic body allows the inspector to observe any seam disturbance or bubble formation that indicates an active leak path during the test.
- Transparent Impact-Resistant Plastic Construction: The transparent plastic body allows the operator to observe the seam surface within the test area during vacuum application – providing visual confirmation of seam condition, detection of bubble formation or membrane disturbance that indicates an active leak path through the seam, and direct observation of any seam anomaly that might contribute to a vacuum hold failure before the manometer reading confirms the pressure drop.
- Durable Perimeter Seal for Consistent Vacuum Integrity: The perimeter seal is designed for durability across extended field use – maintaining the vacuum-tight contact between the box and the membrane surface that is required for valid test results at every test position throughout the inspection programme, without the seal performance degradation that reduces vacuum integrity and introduces false-negative test results when testing instruments are used intensively across large installations.
- Bar and inHg Dual-Scale Manometer: The manometer reads in both bar and inHg, providing pressure display in the units required by different project quality assurance standards – relevant on civil infrastructure projects in Oman and the GCC where international project specifications may reference either metric or imperial pressure units for vacuum seam testing acceptance criteria.
- Thumb-Pressure Vent for Single-Operator Testing Efficiency: The vent releases under thumb pressure at the end of each test position, enabling the VACUUM BOX to be repositioned to the next seam section quickly and without requiring a second operator to manage vent release – allowing the complete test sequence of position, vacuum application, hold, manometer reading, vent, and reposition to be performed continuously and efficiently by a single quality inspector across the full seam inspection programme.
- Ergonomic Handle for Field Carry and Positioning: The ergonomic handle allows the VACUUM BOX to be carried comfortably between test positions across the geomembrane installation area – including on sloped embankment sections, around reservoir perimeters, and across the irregular terrain of active civil project sites where the inspector must move continuously between test positions throughout the working inspection session.
- High-Quality Fittings with Clear Arrangement: The vacuum connection fittings are clearly arranged on the instrument body, enabling straightforward connection to the Leister VACUUM PUMP hose without confusion or incorrect connection that would compromise the vacuum circuit – supporting rapid, reliable equipment setup at the start of each inspection session and confident reconnection when the pump hose is disconnected between test areas.
- Designed for Use with Leister VACUUM PUMP: The necessary vacuum is generated using the Leister VACUUM PUMP, which connects to the VACUUM BOX to apply and hold the required vacuum level consistently across all test positions without operator pumping effort – enabling the inspector to focus on manometer reading, visual observation, and positioning accuracy rather than vacuum generation during the test sequence.
Geomembrane Weld Seam Vacuum Testing Applications for the VACUUM BOX in Oman and the GCC
- Landfill Containment Liner Long Seam Run Inspection: Provides rapid coverage of the straight, long seam runs on landfill cell geomembrane primary and secondary liner panels – where the 810 x 310 mm test area reduces the number of individual test positions required to cover each panel seam by comparison with smaller testing instruments, enabling comprehensive vacuum testing of large-area liner installations within the inspection time available during active installation programme quality review windows.
- Reservoir and Canal Liner Seam Quality Verification: Tests overlap weld seams on large-area reservoir liner and canal waterproofing geomembrane installations across Oman and the GCC – where the large test area of the VACUUM BOX enables systematic vacuum testing coverage of the full installed seam network on substantial hydraulic infrastructure liner programmes within the project inspection schedule constraints.
- Civil Environmental Barrier and Geomembrane Inspection: Supports the systematic pre-acceptance vacuum testing programme on civil environmental barrier liner systems – where the VACUUM BOX covers field seam sections and the VACUUM BELL addresses corners and detail areas, together providing complete non-destructive seam quality verification across the installed liner network before formal project acceptance and liner system commissioning.
- Mine Containment Liner and Heap Leach Pad Seam Testing: Tests geomembrane weld seams on mine tailings containment, heap leach pad, and process area liner installations where environmental compliance requires demonstrated seam integrity across the full liner area before the liner is placed into service – with the VACUUM BOX’s large test area enabling efficient coverage of the extensive seam networks that large mine liner installations generate.
- Pre-Acceptance Quality Inspection Programme on Large Civil Liner Projects: Functions as the primary field vacuum testing instrument for quality inspectors conducting systematic pre-handover seam verification on large geomembrane liner installations – covering the long straight seam runs that constitute the majority of total seam length on large civil liner projects with the inspection efficiency that the VACUUM BOX’s rectangular format provides, before formal acceptance of the installed liner system by the project client.
Leister VACUUM BOX – Available Through iBuild, Authorised Leister Distributor in Oman
iBuild is an authorised Leister distributor in the Sultanate of Oman, providing civil engineering contractors, geomembrane installation teams, quality control engineers, and environmental project managers with direct access to the VACUUM BOX alongside the compatible Leister VACUUM PUMP, the square VACUUM BELL for corner and detail testing, and the full range of Leister geomembrane quality assurance instruments. As a manufacturer-authorised technical partner, iBuild supports vacuum testing programme instrument selection – advising on when to deploy the VACUUM BOX for field seam coverage and the VACUUM BELL for corner and confined geometry testing – to enable comprehensive and efficient weld seam quality verification across the full range of civil geomembrane installation project types in Oman and the GCC.
For civil engineering contractors, geomembrane installation specialists, and quality assurance engineers across Oman and the GCC requiring a robust, large-format rectangular vacuum testing instrument that covers geomembrane overlap weld seams efficiently at 0.5 bar sensitivity with transparent observation, durable seal integrity, and single-operator thumb-pressure operation, iBuild is the authorised local source for the Leister VACUUM BOX – backed by manufacturer authority and in-country technical support.
Technical Data
| Article Number | 152.981 |
| Max. Vacuum | 0.5 bar |
| Manometer Scale | bar, inHg |
| Test Area | 810 x 310 mm / 31.89 x 12.20 in |
| Length | 830 mm |
| Width | 320 mm |
| Height | 150 mm |
| Weight | 3.8 kg |
| Country of Origin | Switzerland |